INTRODUCTION

Electromagnetic Compatibility (EMC), as we know, is the ability of equipment and systems to function as designed in their intended operational environment without adversely disturbing or being affected by other equipment or systems. Electromagnetic Compatibility (EMC) has become a topic of serious concern for manufacturers and users of electronic products in the Global Market. Design of an electronic equipment to comply with National/International EMC Standards calls for controlling the emissions from equipment and improving its immunity to external EMI. Undesired emissions may originate from equipment at the component, PCB and enclosure levels. Keeping in mind the EMC testing needs of the industry in the western region of the country, SAMEER took initiative to set up EMI/EMC Test Facilities at their Navi Mumbai Campus. 

EMC centre, a part of EMI/EMC Division, SAMEER – Mumbai, is located at Navi Mumbai campus, approx. 30 kms away from head office at Powai. The centre was established in the year 2005 for catering to the EMC testing needs of the industry. The division comprises of experienced team of scientists and engineers working in the area of EMI/EMC having vast experience on Space and Defense systems requiring EM compliance. Challenges of suggesting cost effective solutions for meeting EM standard for its compliance are also taken up by the division by way of  providing consultancy services. The team also provides testing services for large installations and rolling equipment like suburban (Mono / Metro) and mainline trains. 

The Division follows Quality Management System and it is accredited by National Accreditation Board for Standardization and Calibration Laboratories (NABL) as per ISO/IEC 17025:2005. This helps laboratory in keeping abreast with the latest developments in technology and standards. It in-turn assists us in rendering quality services to the manufacturers to meet regulatory requirements for product reliability to their satisfaction. 

The division provides the following  test and calibration services

EMI/EMC tests  

  • Accredited EMI/EMC measurement services at permanent location (in-house) as well as installation sites for compliance to EMC standards (as per Civilian and Military standards).
  • Design consultancy services for compliance to EMI/EMC standards
  • RF noise measurement (survey), RF mapping of large structures, Radiated emission measurements for large installations
  • Measurement of Shielding Effectiveness (S.E.) required for validation of shielded enclosures
  • Radiated emission measurement of moving objects like Mono, Metro and mainline trains (railways). The group has rendered their services for radiated emission measurement of trains to various establishments like Mumbai Mono rail and suburban trains as per EN & IEC standards (IEC 50121-3-1, IEC 50121-3-2, IEC 50121-2).
  • Organising short duration workshops for imparting training on EMI/EMC

EMI/EMC instrument calibration services as per relevant IEC/ANSI/IEEE standards

  • Accredited Calibration services for EMC test instruments and accessories
    • LISNs/ISNs/CDNs/Attenuators/Capacitive Coupling Clamps/Directional Couplers
    • Surge/EFT/ESD Generators
    • Signal Generators/Amplifiers

Electrical Safety & Environmental test services

Electrical Safety testing services for IT, audio / video equipment and household appliances, environmental testing, mechanical shock & vibration.

TEST FACILITIES AVAILABLE

 

1   1.EMI/EMC Tests (Civilian & Military standards) 

               i.  Emission Tests

 

Civilian Standard (CISPR/IEC/FCC)

Military standard (MIL-STD-461)

Conducted Emission as per FCC Part 15 & CISPR 11/14/15/22/32

Conducted emission as per CE 101

Radiated Emission Testing as per CISPR 11/22/32

Conducted emission as per CE 102

Harmonics Emission as per IEC/EN 61000-3-2

Radiated emission as per RE 101

Flicker emission as per IEC/EN 61000-3-3

Radiated emission as per RE 102

   

           ii.Susceptibility / Immunity Tests

 

Civilian Standard (IEC 61000-4-X)

Military standard (MIL-STD-461)

Electro Static Discharge test as per IEC 61000-4-2

Conducted susceptibility as per CS 101

Radiated Susceptibility Testing as per IEC/EN 61000-4-3

Conducted susceptibility as per CS 109

Electric Fast Transient test as per IEC/EN 61000-4-4

Conducted susceptibility as per CS 114

Surge test as per IEC/EN 61000-4-5

Conducted susceptibility as per CS 115

RF conducted susceptibility test as per IEC/EN 61000-4-6

Conducted susceptibility as per CS 116

Power Frequency Magnetic Field test as per IEC/EN 61000-4-8

Radiated susceptibility as per RS 101

Voltage dips and interruptions as per IEC/EN 61000-4-11

Radiated susceptibility as per RS 103

Ring & damped Oscillatory wave test as per IEC/EN 61000-4-12

 

Dips on DC Voltage supply as per IEC/EN 61000-4-29

 

 2.  Calibration of EMI/EMC test instruments and accessories

  i.    RF Parameters (coupling / Decoupling, correction factors)

a.     Insertion Loss (Correction factor for LISNs & ISNs)

b.     Attenuation

c.     Impedance

d.     Isolation

e.     Coupling factor (for CDNs, Directional couplers)

f.      VSWR / Reflection co-efficient

g.     Frequency (150 kHz – 3 GHz)

h.     RF field / power level

i.      Harmonic level (upto 3rd harmonic)

j.      Amplifier gain

ii.    DC / Pulse parameters (for Impulse Generator - ESD, EFT & Surge)

a.     Rise time, Fall time, Pulse width

b.     High Voltage Pulse level (Common & differential mode)

 3.  Safety test facility

  1. Electrical Safety tests
  1. Environmental tests
  1. Insulating Material test

 

CONTACT DETAILS

 

EMC Centre-SAMEER, Sector-7, Rain Tree Marg,

CBD Belapur, Navi Mumbai - 400 614. India

 

Telephone:

 

1.    Customer Care Cell - (+91)- 022 - 2759 3121, 2756 4056

2.    EMI/C testing Services - (+91)- 022 – 27593116/17/18

3.    EMI/C Instrument Calibration Services – (+91) 022 – 27593118, 27593126

4.    Electronic Safety & Environmental testing Services - (+91)- 022 - 27593132

 

Fax:

 

    (+91)-022 - 2756 4062 (Navi Mumbai Centre), 2572 3254 (Powai campus)

 